Supplementary data for "Hygrothermal performance of six insulation systems for internal retrofitting solid masonry walls" Nickolaj Feldt Jensen Søren Peter Bjarløv Carsten Rode Birgitte Andersen Eva B. Møller 10.11583/DTU.12458207.v1 https://data.dtu.dk/articles/dataset/Supplementary_data_for_Hygrothermal_performance_of_six_insulation_systems_for_internal_retrofitting_solid_masonry_walls_/12458207 <div>Supplementary data for: N.F. Jensen,<sup> </sup>S.P. Bjarløv, C. Rode, B. Andersen, E.B. Møller, 2020, "Hygrothermal performance of a phenolic foam insulation system with a closed cell structure and a lime-cork insulating plaster for internal retrofitting solid masonry walls"</div><div>The article is in review for Journal of Building Physics<div>The authors are awaiting link/DOI for the article.<br></div></div><div><br></div><div>The datasets comprises: </div><div><div>1) Measured temperature and relative humidity (Hourly data and 96-hour running average).</div><div>2) Mathematical mould-growth predictions with the VTT model.</div><div>3) On-site fungal tests with the Mycometer method.</div><div>4) On-site pH tests</div><div>5) Photos for installation of the Phenolic foam and lime-cork insulating plaster systems.</div></div> 2020-06-22 11:48:51 internal insulation solid masonry field study hydrophobisation mould modelling on-site mould observations Phenolic foam insulation Lime-cork Insulating plaster embedded wooden elements diffusion-open capillary active diffusion-tight Building Science and Techniques